A Novel Multi-Patient Mechanical Ventilator Drive System Using Continuously Variable Transmission and Reverse Gearbox

Endi Sailul Haq, Devit Suwardiyanto, Sepyan Purnama Kristanto, Endang Setyati

Abstract


In the present study, a new model of multi-mechanical ventilator drive using a continuously variable transmission (CVT) cone was presented as the main driving force to control the pressure of the BVM Ambu bag, which can produce different airflow pressures for several patients, and using a worm gear to isolate the CVT cone so as not to get the load generated from the pressure of the Ambu bag. In addition, the reverse gear transmission system is used to control the direction of rotation, and the leadscrew is used to change the rotation according to the linear translational motion of the Ambu bag pushing arm. In this system, a DC motor is used as the main driver, and a flexible tuner cable that can be connected to other ventilators is utilized. This research shows that this CVT system can reduce rotation down to 60.35% and increase rotation up to 148.26% with constant rotation input. There are 23 points of change in the position of the belt, which causes variations in the pouch pressing. The system can produce the highest and lowest pressure value at 20.2 and 0.4 cm H2O. Simultaneously, the rotation of the flexible tuner cable showed no significant change. However, the weakness in the CVT system is the belt friction with the cone surface causing heat and slippage. In this case, the selection of the appropriate material and belt shape can cause belt displacement easiness that important in appropriate speed for applied pressure.


Keywords


Multi-mechanical ventilator; CVT cone; worm gear; reverse gearbox; Ambu bag; Covid-19.

Full Text:

PDF

References


Q. Ding, P. Lu, Y. Fan, Y. Xia, and M. Liu, “The clinical characteristics of pneumonia patients coinfected with 2019 novel coronavirus and influenza virus in Wuhan, China,†J. Med. Virol., vol. 92, no. 9, pp. 1549–1555, Sep. 2020, doi: 10.1002/jmv.25781.

R. Djalante et al., “Review and analysis of current responses to COVID-19 in Indonesia: Period of January to March 2020,†Prog. Disaster Sci., vol. 6, p. 100091, Apr. 2020, doi: 10.1016/j.pdisas.2020.100091.

W. R. P. COVID-19, “Peta Sebaran,†covid19.go.id. https://covid19.go.id/peta-sebaran (accessed Mar. 20, 2021).

Y. Yi, P. N. P. Lagniton, S. Ye, E. Li, and R.-H. Xu, “COVID-19: what has been learned and to be learned about the novel coronavirus disease,†Int. J. Biol. Sci., vol. 16, no. 10, pp. 1753–1766, Mar. 2020, doi: 10.7150/ijbs.45134.

A. Das, “Modelling and Optimisation of Mechanical Ventilation for Critically Ill Patients,†p. 166.

J. S. Han et al., “Personalized Ventilation to Multiple Patients Using a Single Ventilator: Description and Proof of Concept,†Crit. Care Explor., vol. 2, no. 5, p. e0118, May 2020, doi: 10.1097/CCE.0000000000000118.

P. L. Silva and P. R. M. Rocco, “The basics of respiratory mechanics: ventilator-derived parameters,†Ann. Transl. Med., vol. 6, no. 19, p. 376, Oct. 2018, doi: 10.21037/atm.2018.06.06.

O. Garmendia et al., “Low-cost, easy-to-build noninvasive pressure support ventilator for under-resourced regions: open source hardware description, performance and feasibility testing,†Eur. Respir. J., vol. 55, no. 6, Jun. 2020, doi: 10.1183/13993003.00846-2020.

V. O. Kheyfets, S. Lammers, J. Wagner, K. Bartels, and B. Smith, “Use of a Single Ventilator to Support Multiple Patients: Modeling Tidal Volume Response to Heterogeneous Lung Mechanics,†medRxiv, p. 2020.04.07.20056671, Apr. 2020, doi: 10.1101/2020.04.07.20056671.

S. Zulfiqar, H. Nadeem, Z. Tahir, M. Mazhar, and K. M. Hasan, “Portable, Low Cost, Closed-Loop Mechanical Ventilation Using Feedback from Optically Isolated Analog Sensors,†in TENCON 2018 - 2018 IEEE Region 10 Conference, Oct. 2018, pp. 1913–1916, doi: 10.1109/TENCON.2018.8650277.

S. M. Kim, U. H. Lee, H. J. Kwon, J.-Y. Kim, and J. Kim, “Development of an IoT Platform for Ocean Observation Buoys,†IEIE Trans. Smart Process. Comput., vol. 6, no. 2, pp. 109–116, 2017, doi: 10.5573/IEIESPC.2017.6.2.109.

J. Herrmann, A. Fonseca da Cruz, M. L. Hawley, R. D. Branson, and D. W. Kaczka, “Shared Ventilation in the Era of COVID-19: A Theoretical Consideration of the Dangers and Potential Solutions,†Respir. Care, vol. 65, no. 7, pp. 932–945, Jul. 2020, doi: 10.4187/respcare.07919.

A. Vasan et al., “MADVent: A lowâ€cost ventilator for patients with COVIDâ€19,†Med. Devices Sens., Jun. 2020, doi: 10.1002/mds3.10106.

E. Mobedi and M. İ. C. Dede, “A Continuously Variable Transmission System Designed for Human–Robot Interfaces,†in Mechanism and Machine Science, Singapore, 2021, pp. 29–41, doi: 10.1007/978-981-15-4477-4_3.

M. V. ÄŒavić, M. M. PenÄić, and M. Ž. Zlokolica, “Adaptive continuously variable transmission used for maintaining stationary regime of driving machine,†Therm. Sci., vol. 20, no. suppl. 2, pp. 525–536, 2016.

J. B. Mahakal and D. Kamble, “Investigation of Performance of Plastic Worm Gear in Power Window Gearbox Application,†2016. /paper/Investigation-of-Performance-of-Plastic-Worm-Gear-Mahakal-Kamble/d7a5afa1bfd70d815d79571c8b3a870a99a8eae9 (accessed Mar. 20, 2021).

A. K. Ajay, A. J. Vadakkekara, A. Krishnan, A. K. V., A. Paul, and J. P. N., “Reverse gear mechanism on a motor cycle,†AIP Conf. Proc., vol. 2247, no. 1, p. 020002, Jul. 2020, doi: 10.1063/5.0004186.

K. R. S. Ansari, A., B. Shukla, P. J., and Khan, W., “Design & fabrication of reverse gear box for go-kart & for handicapped vehicle,†Int. J. Recent Trends Eng. Res., vol. 3, no. 3, pp. 401–408, March 2017.

Ellis, G., Observers in Control System. US: Academic Press, 2002.

H. Nishizawa, H. Yamaguchi, H. Suzuki, M. Osawa, K. Iwatuki, and Y. Oshiumi, “Friction characteristics analysis for clamping force setup in metal V-belt type CVT,†SAE Tech. Pap., vol. 40, no. 3, pp. 14–20, 2005, doi: 10.4271/2005-01-1462.

B. Dafilou, D. Schwester, N. Ruhl, and A. Marques-Baptista, “It’s In The Bag: Tidal Volumes in Adult and Pediatric Bag Valve Masks,†West. J. Emerg. Med., vol. 21, no. 3, pp. 722–726, May 2020, doi: 10.5811/westjem.2020.3.45788.




DOI: http://dx.doi.org/10.18517/ijaseit.11.6.13754

Refbacks

  • There are currently no refbacks.



Published by INSIGHT - Indonesian Society for Knowledge and Human Development