Effectiveness of Truss Supporting During Replacement of Damaged Column in a High-Rise Frame Structure Building
Abstract
Truss supporting (TS) is a technique to support a building frame for replacing column when its stiffness reduces due to any kind of damage. This paper deals about the effectiveness of TS during replacement of damaged column in a high-rise frame structure building. For the case study of the effectiveness of TS, six columns that are damaged columns at different positions in the ground and first floors were taken into consideration. A suitable type of truss was modelled to transfer the load of damaged column to the lower column just below the damaged column. The numerical analysis of the 2-D frame with undamaged columns, damaged column and damaged column with truss supporting, was carried out using finite element software STAAD Pro 2004. The deflection, axial force, shear force and bending moment of the structural elements (beam & column) for TS case were obtained almost same as their design values
Keywords
Truss Supporting; Numerical Analysis; Column Replacement and Frame Structure
Full Text:
PDFDOI: http://dx.doi.org/10.18517/ijaseit.1.6.122
Refbacks
- There are currently no refbacks.
Published by INSIGHT - Indonesian Society for Knowledge and Human Development